AT-S63 Management Software Menus User’s Guide
Section II: Advanced Operations 213
For example, the setting of DEFAULT assigns all port mirroring events
a code of 22 and all encryption key events a code of 4.
Your other option is to assign the same numerical code to all events
from a switch using one of the following facility level settings:
1 - LOCAL1
2 - LOCAL2
3 - LOCAL3
4 - LOCAL4
5 - LOCAL5
6 - LOCAL6
7 - LOCAL7
Each setting represents a predefined RFC 3164 numerical code. The
code mappings are listed in Table4.
9 Clock daemon Time- based modules:
- TIME (system time and SNTP)
- RTC
22 Local use 6 Physical interface and data link
modules:
- PCFG
- PMIRR
- PTRUNK
- STP
- VLAN
23 Local use 7 SYSTEM events related to major
exceptions.
16 Local use 0 All other modules and events.
Table 4. Numerical Code and Facility Level Mappings
Numerical
Code Facility Level Setting
17 LOCAL1
18 LOCAL2
19 LOCAL3
Table 3. Applicable RFC 3164 Numerical Code and AT-S63 Module
Mappings (Continued)
Numerical
Code RFC 3164 Facility AT-S63 Module