AT-S63 Management Software Menus User’s Guide
Section II: Advanced Operations 223
7. Repeat steps 5 and 6 to adjust any other variables necessary to define
the traffic flow for this classifier.
8. After configuring the necessary variables, type C to select Create
Classifier.
The switch creates the classifier. If any of the settings are
incompatible, the system displays an error message.
9. To create more classifiers, repeat this procedure starting with step 3.
10. To permanently save your change, return to the Main Menu and type S
to select Save Configuration Changes.
11. To add classifiers to an ACL, refer to “Creating an ACL” on page232.
To add classifiers to a QoS policy, refer to “Managing Flow Groups” on