AT-S62 Command Line User’s Guide

SET SWITCH PORT RATELIMIT

Syntax

set switch port=all [rate=value] [bcastratelimiting=yesnoonofftruefalse enableddisabled] [mcastratelimiting=yesnoonofftruefalse enableddisabled] [unkucastratelimiting=yesnoonofftruefalse enableddisabled]

Parameters

 

 

port

Specifies all ports on the switch. This feature

 

cannot be configured on a per-port basis. You

 

must specify ALL.

 

rate

Specifies the number of ingress packets the switch

 

ports accept each second. This setting applies all

 

packet types that have their rate limit enabled. The

 

range is 0 to 262,143.

 

bcastratelimiting

Enables or disables rate limiting for ingress

 

broadcast packets. Settings for this parameter are:

 

yes, on, true, enabled

Activates broadcast

 

 

packet rate limit on the

 

 

port. The values are

 

 

equivalent.

 

no, off, false, disabled

Deactivates broadcast

 

 

packet rate limit on the

 

 

port. The values are

 

 

equivalent.

mcastratelimiting

Enables or disables rate limiting for ingress

 

multicast packets. Settings for this parameter are:

 

yes, on, true, enabled

Activates multicast

 

 

packet rate limit on the

 

 

port. The values are

 

 

equivalent.

 

no, off, false, disabled

Deactivates multicast

 

 

packet rate limit on the

 

 

port. The values are

 

 

equivalent.

unkucastratelimiting

Enables or disables rate limiting for unknown

 

ingress unicast packets. An unknown unicast

 

packet is a packet whose destination MAC

 

address is not stored in the switch’s MAC address

171

Page 171
Image 171
Allied Telesis management software layer 2+ fast ethernet switches manual SET Switch Port Ratelimit