SHOW POE STATUS

Syntax

show poe status [port=port]

Parameter

 

port

Specifies a port. You can specify more than one port at

 

a time. You can specify the ports individually (for

 

example, 5,7,22), as a range (for example, 18-23), or

 

both (for example, 1,5,14-22).

Description

 

Entering this command without specifying a port displays the following

PoE information:

Max Available Power - The total available power for PoE supplied by the switch. This value is 400 W for the AT-8524POE switch.

Consumed Power - The amount of power being used by the powered devices.

Available Power - The amount of power available for additional powered devices.

Power Usage - The amount of power currently consumed by the powered devices connected to the switch. The value is give as a percentage of the total amount of power available.

Min Shutdown Voltage - The minimum threshold voltage at which the switch shuts down PoE. If the power supply in the switch experiences a problem and the output voltage drops below this value, the switch shuts down PoE on all ports. This value is not adjustable.

Max Shutdown Voltage - The maximum threshold voltage at which the switch shuts down PoE. If the power supply in the switch experiences a problem and the output voltage exceeds this value, the switch shuts down PoE on all ports. This value is not adjustable.