AT-S62 Command Line User’s Guide

SET DOS SMURF

Syntax

set dos smurf port=port state=enabledisable

Parameters

 

 

port

Specifies the switch ports on which you want to

 

enable or disable SMURF defense. You can select more

 

than one port at a time.

state

Specifies the state of the SMURF defense. The options

 

are:

 

 

enable

Activates the defense.

 

disable

Deactivates the defense. This is the default.

Description

This command activates and deactivates the SMURF DoS defense.

This DoS attack is instigated by an attacker sending a Ping request containing a broadcast address as the destination address and the address of the victim as the source of the Ping. This overwhelms the victim with a large number of Ping replies from other network nodes.

A switch port defends against this form of attack by examining the destination addresses of ingress Ping packets and discarding those that contain a broadcast address as a destination address.

To implement this defense, you need to specify the IP address of any device on your network, preferably the lowest IP address, and a mask using SET DOS on page 368. The switch uses the combination of the two to determine your network’s broadcast address. Any ingress Ping packets containing the broadcast address are discarded.

This defense mechanism does not involve the switch’s CPU. You can activate it on as many ports as you want without having it negatively impact switch performance.

Example

The following command activates this defense on port 17:

set dos smurf port=17 state=enable

373

Page 373
Image 373
Allied Telesis management software layer 2+ fast ethernet switches manual SET DOS Smurf, Set dos smurf port=17 state=enable