Chapter 17: Event Log and Syslog Server Commands

DISABLE LOG OUTPUT

Syntax

disable log output[=id_number]

Parameters

 

output

Specifies the ID number of the syslog server

 

definition to disable. The range is 2 to 20. You can

 

specify only one ID number at a time. Omitting an ID

 

number disables all syslog server definitions.

Description

 

This command disables the specified syslog server definition and stops the switch from sending any further system events to the defined server. To permanently remove a syslog server definition, see “DESTROY LOG OUTPUT” on page 266. To enable the syslog server definition again, see “ENABLE LOG OUTPUT” on page 270.

Examples

The following command disables (but does not delete) the syslog server definition with the ID number 7:

disable log output=7

The following command disables all syslog server definitions:

disable log output

268

Page 268
Image 268
Allied Telesis management software layer 2+ fast ethernet switches manual Disable LOG Output, Disable log output=idnumber