5-214 Compact T1 - Release 6.1
CLI Commands
show
show impedance
The show impedance command displays the impedance settings for FXS 5G card.
Syntax: show impedance
Example: show impedance
Index Impedance CODEX Country
----- ------------------------------- ----- -------------------
1 120 Ohms + (.110µF || 820 Ohms) A-law Norway
2 150 Ohms + (.047µF || 510 Ohms) A-law Malaysia
3 150 Ohms + (.072µF || 830 Ohms) A-law Belgium
4 200 Ohms + (.100µF || 680 Ohms) A-law China
5 215 Ohms + (.137µF || 1k Ohms) A-law France
6 220 Ohms + (.115µF || 820 Ohms) A-law Austria, Germany,
Mexico, Switzerland
7 220 Ohms + (.120µF || 820 Ohms) A-law Australia
8 270 Ohms + (.120µF || 910 Ohms) A-law Finland
9 300 Ohms + (.220µF || 1k Ohms) A-law United Kingdom
10 370 Ohms + (.310µF || 620 Ohms) A-law New Zealand
11 400 Ohms + (.033µF || 500 Ohms) A-law Denmark
12 400 Ohms + (.050µF || 500 Ohms) A-law Greece
13 600 Ohms A-law Korea, Indonesia,
Italy, Poland,
Russia, Spain,
Thailand, China
14 600 Ohms + 1.00µF µ-law Japan
15 600 Ohms + 1.50µF A-law Saudi Arabia
16 600 Ohms + 2.16µF µ-law Korea
17 800 Ohms A-law Netherlands
18 900 Ohms A-law Brazil
19 900 Ohms + 2.16µF µ-law USA, Taiwan
Note: In general, µ-Law settings are used for T1 applications, A-Law settings are used for
E1 applications.