Compact T1 - Release 6.1 6-9

T1 Controller Card

Configuration

DIP Switch Settings
On the front of the TDM Controller card are DIP switches you can use to configure the unit locally.

Switch Function Description

ACO Alarm Cut
Off 0 = Alarm contacts enabled (close when alarm occurs).
Default.
1 = Alarm contacts disabled (open).
ST Self Test 0 = Normal operation. Default.
1 = Perform Self Test.
OPT Spare
RST Reset 0 = User-configured operation. Defau lt.
1 = Reset configuration to factory defaults, and reset CLI
password.
T1-1
T2-1 Line Coding 0 = B8ZS. Default.
1 = AMI
T1-2
T2-2 Line
Loopback 0 = Loopback off. Default.
1 = Loopback on
T1 3-4
T2 3-4 Framing 0 = ESF (Extended Superframe). Default.
1 = D4
T1 5 - 6
T2 5 - 6 Signaling
Switch 3 Switch 4 Switch 5 Switch 6 Setting
0 1 1 1 TR-08 A-Shelf with FDL, 16-bit Alarm frame
1 0 0 0 TR-08 A-Shelf with FDL, 13-bit Alarm frame
1 0 0 1 TR-08 A-Shelf with FDL disabled
1 0 1 0 TR-08 B-Shelf
0 0 0 0 Loop Start/Ground Start. Default.
0 0 0 1 E&M Immediate Start with ringback. (used for D3 PLAR
and DPT)
0 0 1 0 E&M Immediate Start with ringback and Calling Party
Disconnect (CPD)