3-2 Compact T1 - Release 6.1
Electrical Installation and Cabling
Compliant Installation
Compliant Installation
1. Connect all of the signal cables as shown in the illustration above, and secure
them with a plastic tie. Dress the signal cabl es toward the left of the unit.
2. If using the 115V Power Supply, connect the -48 VDC battery power cable
3. Secure the ground lugs to the terminals using the nuts provided.
4. Secure the power cable and the ground cable with a plastic tie (not included).
Keep these cables separate from the signal cables.
5. Terminate each signal cable to its appropriate connector.
6. Secure the signal cables using the small holes along the bottom of the rack and
plastic ties (not included).
NOTE: It is important that the Signal Cables are secured separately from
the Power Cables, for proper equipment operation.
PowerCord
-48VDC Battery Power
AlarmWiring

Signal Cables

Power Cables

GroundingCable
FerriteBead
withcable loop
RS-232craft port
25-pairtelco connector
25-pairtelco connector
10Base-TEthernet
T1/E1connectors
FerriteBeads
arein red