5-74 Compact T1 - Release 6.1
CLI Commands
set
set clock
Use the set clock command to set the master transmit clock. The primary master clock source
may be used to clock each DS1 transmitter. The clock circuit automatically switches to the
secondary clock source if the primary clock fails.
Syntax: set {clock1|clock2} {source}
Example: set clock1 a:1
To set the primary master clock source to A:1.
Example: set clock2 1:2
To set the secondary master clock source to Quad T1 card in slot 1 source
selected.
{clock1}
Set primary master transmit clock source.
{clock2}
Set secondary master transmit clock source.
{source}
Set the clock source to one of the following:
set date
Use the set date command to set the date.
Syntax: set date {mm/dd/yyyy}
Example: set date 1/1/2001
The example will set the date to January 1, 20001.
{mm/dd/yyyy}
bri-addr Clock recovered from the BRI port on the BRI card (BRI card must be in
LUNT and 3DS0 mode)
ds1-addr Clock recovered from the DS1 receiver
internal Internal stratum 4E oscillator
mm Represents the month. Range is 1-12, single digits can be entered.
dd Represents the Day. Range is 1-31, single digits can be entered.
yyyy Represents the year. Range is 1999-2106.