10-6 Compact T1 - Release 6.1
OCU-DP Card
Technical Specifications
Technical Specifications
Controller Software Required
T1 Controller
lRelease 3.2 or higher is required
Service Interface
lSingle-port OCU-DP interface
-One RJ-48S front-panel jack
-Strap selections for rear-panel RJ-21X telco connector
lFour-port OCU-DP interface
-Four RJ-48S front-panel jack
-Strap selections for rear-panel RJ-21X telco connector
Network Interface
lEach OCU port DS0 cross-connected to T1 port
Loopbacks
OCU, CSU and DSU:
lManual loopbacks activate via CLI
lNon-latching loopbacks activate via network code
lLatching loopbacks activate via network code
Clocking
lLoop-timed from any T1 in the platform
lSources clock to the DTE device