Compact T1 - Release 6.1 5-79
CLI Commands
set
set ethernet ip address
Use the set ethernet ip address command to set the Ethernet address for the Compact T1.
Syntax: set ethernet ip address {ip-addr} [mask]
Example: set ethernet ip address 172.26.100.25 255.255.255.0
Sets the Adit IP address to 172.26.100.25, and a subnet mask of 255.255.255.0.
{ip-addr}
Set the IP address for the Compact T1, using the form xxx.xxx.xxx.xxx, where xxx is a
number from 0 to 255.
[mask]
Set the subnet mask, using the form xxx.xxx.xxx.xxx, where xxx is a n umber from 0 to 255.
This is an optional setting.
set (fxo)
Use the set (fxo) command to setup one/all of the voice channels of an FXO card. The command
specifies the list of voice channels within that card, and the setting to apply.
Syntax: set {fxo-addr} {setting}
Example: set 2:1 signal ls
Set the FXO on slot 2, port 1 to signaling type loop start.
{fxo-addr}
List of voice channels to apply setting to, in the form {slot:port}.
{setting}
slot Slot number 1 - 6, location of the FXO card
port Port number or range
rxgain The receive level range is -9 to +7 (db). Available values are -9, -7, -6, -5,
-4, -3, -2, 0, 2, 3, 4, 5, 6, and 7
signal Set the DS0 signaling type
dpt Set the DS0 to Dial Pulse Terminate
gs Set the DS0 to Ground Start signaling
ls Set the DS0 to Loop Start signaling
lscpd Set the DS0 to Loop Start Calling Party Disconnect
txgain The transmit level range is -9 to +7 (db). Available values are -9, -7, -6,
-5, -4, -3, -2, 0, 2, 3, 4, 5, 6, and 7