5-86 Compact T1 - Release 6.1
CLI Commands
set
set (ocudp) baud
Use the set (ocudp) baud command to configure the Baud Rate for OCU-DP ports.
Syntax: set {ocudp-addr} baud {rate}[sw56|sw56cp]
Example: set 3:2 baud 2400
Set the baud rate on port 2 to 2400, on the OCU-DP card in slot 3
{ocudp-addr}
The {slot:port} address of the OCU-DP card you want to apply the changes to.
{rate}
slot Slot number (1-6) where the OCU-DP is located
port Port number or range.
2400 Set OCU-DP baud rate to 2400
4800 Set OCU-DP baud rate to 4800
9600 Set OCU-DP baud rate to 9600
19200 Set OCU-DP baud rate to 19200
38400 Set OCU-DP baud rate to 38400
56000* Set OCU-DP baud rate to 56000 (Default)
sw56 Set to switched 56 service
sw56cp Set to switched 56 service with call progress capability. Sends
special call progress CMI codes to DSU.
64000 Set OCU-DP baud rate to 64000