OMNISCANNER
The fiber cables included with your OMNIFiber kit are duplex launch cables with
8.3 The Reference Methods
OMNIFiber has
It is very important that the transmitter (TX port) connections are not disturbed after the reference value is established
NOTE
When a connector is removed and then reattached, it is unlikely to go back into the exact same position. As a result, measurements will change when connections are made or broken.
OMNIFiber measures two fibers of a duplex link in one Autotest operation. Four reference values will be stored, two from OMNIScanner to OMNIRemote (TX - RX), the others from OMNIRemote to OMNIScanner (TX - RX).
8.3.1METHOD B: ONE JUMPER REFERENCE METHOD
This method is used when the link includes:
•the loss of one connection at the near end cross connect
•the loss of one connection at the far end cross connect/outlet
•the loss of the cable plant
116