Black Box TS1002A, TS1003A, TS1000A-R5 manual Press ESC to exit the Attenuation screen

Models: TS1000A-R5 TS1003A TS1002A

1 153
Download 153 pages 15.93 Kb
Page 85
Image 85

CHAPTER 5: Measurements

Press ESC to exit the ATTENUATION screen.

NOTE

Attenuation always reports the worst dB value regardless of the Report: setting in the RUN OPTIONS screen.

5.3.5RETURN LOSS

The Return Loss function measures the uniformity of a cable’s impedance. OMNIScanner injects a signal into the cable and measures the reflected signal strength. Return Loss measures the difference between the transmitted signal delivered to the cable and the reflected signal at the input port of the cable. The reflected signal is the result of impedance mismatches in the link under test.

In the RETURN LOSS screen, the worst case margin for all near end and far pairs is shown at the top of the screen.

The pairs are displayed in the column on the left side, followed by the Return

Loss in decibels (dB), the Return Loss margin/limit, and the frequency. The result

for each pair is tagged with a

PASS or

FAIL indicator.

83

Page 85
Image 85
Black Box TS1002A, TS1003A, TS1000A-R5 manual Press ESC to exit the Attenuation screen