OMNISCANNER
NOTE
This method is called “Method A” in
2 m Launch Cable | 2 m Launch Cable |
| RX |
850 nm 1300/1310 nm | TX |
METHOD A
Coupler
TX | 850 nm 1300/1310 nm |
RX |
|
1.Connect a launch cable to the fiber adapter that is attached to OMNIScanner. The black fiber attaches to the TX (transmitter) port and the white fiber to the RX (receiver) port.
2.Connect a launch cable to the fiber adapter that is attached to OMNIRemote. The black fiber attaches to the TX (transmitter) port and the white fiber to the RX (receiver) port.
3.Use a connector adapter to mate the two black fiber connectors.
4.Use a connector adapter to mate the two white fiber connectors.
5.Set the Reference.
6.Disconnect the connectors from the connector adapters without disturbing the fiber connections to the OMNIFibers.
7.Set the connector adapters aside.
8.3.3METHOD C: THREE JUMPER REFERENCE METHOD
This method is used when the link includes:
• the loss of the cable plant
NOTE
This method is called “Method C” in
118