OMNISCANNER

NOTE

This method is called “Method A” in TIA-526-14A and “Method A.2” in TIA-526-7.

2 m Launch Cable

2 m Launch Cable

 

RX

850 nm 1300/1310 nm

TX

METHOD A

Coupler

TX

850 nm 1300/1310 nm

RX

 

1.Connect a launch cable to the fiber adapter that is attached to OMNIScanner. The black fiber attaches to the TX (transmitter) port and the white fiber to the RX (receiver) port.

2.Connect a launch cable to the fiber adapter that is attached to OMNIRemote. The black fiber attaches to the TX (transmitter) port and the white fiber to the RX (receiver) port.

3.Use a connector adapter to mate the two black fiber connectors.

4.Use a connector adapter to mate the two white fiber connectors.

5.Set the Reference.

6.Disconnect the connectors from the connector adapters without disturbing the fiber connections to the OMNIFibers.

7.Set the connector adapters aside.

8.3.3METHOD C: THREE JUMPER REFERENCE METHOD

This method is used when the link includes:

• the loss of the cable plant

NOTE

This method is called “Method C” in TIA-526-14A and “Method A.3” in TIA-526-7.

118

Page 120
Image 120
Black Box TS1003A, TS1002A, TS1000A-R5 manual Method a