OMNISCANNER
The pairs are displayed in the column on the left side, followed by the PS NEXT in decibels (dB), the margin/limit, and the frequency. The result for each pair is
tagged with a | PASS or | FAIL indicator. |
Press or to toggle between the PS NEXT results for OMNIScanner and OMNIRemote.
Press (Graph) to display the PS NEXT graph for the currently highlighted pair. PS NEXT is displayed for the frequency indicated by the cursor position.
Press (Pairs) to view PS NEXT graphs for other pairs.
Press ESC to exit the POWER SUM NEXT screen.
5.3.10 POWER SUM ELFEXT
Power Sum ELFEXT is calculated from the summation of the individual ELFEXT effects on each pair by the other three pairs.
In the POWER SUM ELFEXT screen, the worst case margin for all near and far pairs is shown at the top of the screen.
88