APPENDIX A: Technical Specifications

Instrument Parameter

@100 MHz

@200 MHz

@300 MHz

Residual NEXT

>105 dB

>105 dB

>100 dB

Noise Floor

>100 dB

100 dB

>95 dB

Detector Accuracy

0.2 dB

0.2 dB

0.2 dB

Output Signal Balance

50 dB

45 dB

40 dB

Common Mode Rejection

50 dB

45 dB

40 dB

Port Match Error

0.1 dB

0.2 dB

0.5 dB

Directivity

50 dB

50 dB

45 dB

RL Tracking

0.05 dB

0.05 dB

0.05 dB

RL Source Match

50 dB

45 dB

40 dB

A.15 Wire Map

Finds miswires, opens, shorts, and crossed and split pairs, and presents results in a schematic format

Includes shield test if connected

Uses OMNIRemote for complete mapping of wiring at both ends of the cable

A.16 NEXT

Test all six pair combinations from both directions using OMNIRemote

Frequency Range: 1 to 300 MHz

Dynamic Range: >100dB

Measurement Accuracy: Calculated per TIA error model

Accuracy: Significantly exceeds Level III requirements

Measurement Resolution: 0.1dB

A.17 Return Loss

Measures Return Loss on all four pairs from both directions using OMNIRemote

Frequency Range: 1.0 to 300 MHz

Dynamic Range: > -35 dB

137

Page 139
Image 139
Black Box TS1002A, TS1003A, TS1000A-R5 manual Wire Map, Return Loss