CHAPTER 5: Measurements

The scrollbar indicates that there are more test results. Use the down-arrow on OMNIScanner’s keypad to scroll through the list and view results for the other six pair combinations.

Press or to toggle between the ELFEXT results for OMNIScanner2 and OMNIRemote.

Press (Graph) to display the ELFEXT graph for the currently highlighted pair combination. ELFEXT is displayed for the frequency indicated by the cursor position.

Press (Pairs) to view ELFEXT graphs for other pair combinations.

Press ESC to exit the ELFEXT screen.

5.3.7ACR/BANDWIDTH

Attenuation to Crosstalk Ratio (ACR) is an indication of how much larger the received signal is compared to the Near End Crosstalk (NEXT) on the same pair. ACR is calculated from the measured NEXT and Attenuation. The ACR value is computed at each measured Attenuation frequency. The worst-case ACR is reported for each pair combination.

85