OMNISCANNER

Bandwidth is a measure of the usable frequency range of the link under test. For most networks, this is the highest frequency at which the signal can easily be distinguished from background noise. Depending on the selected Autotest, the worst pair to pair ACR is typically 3 dB.

In the ACR screen, the Bandwidth is displayed at the top of the screen.

The pair combinations are located in the column on the left side, followed by

the measured ACR, the ACR margin/limit, and the frequency. The result for each

pair combination is tagged with a

PASS or

FAIL indicator.

Press or to toggle between ACR results for OMNIScanner and OMNIRemote.

Press (Graph) to view the graph for the currently highlighted pair combination. The values for Attenuation and NEXT are shown at the top of the screen. Attenuation and NEXT graphs are displayed for the frequency indicated by the cursor position.