CHAPTER 5: Measurements

The pairs are displayed in the column on the left side, followed by the PSEFLEXT in decibels (dB), the margin/limit, and the frequency. The result for

each pair is tagged with a

PASS or

FAIL indicator.

Press or to toggle between the PS ELFEXT results for OMNIScanner and OMNIRemote.

Press (Graph) to display the PS ELFEXT graph for the currently highlighted pair. PS ELFEXT is displayed for the frequency indicated by the cursor position.

Press (Pairs) to view PS ELFEXT graphs for other pairs.

Press ESC to exit the POWER SUM ELFEXT screen.

5.3.11POWER SUM ACR

Power Sum ACR is calculated from the Attenuation of the disturbing pair subtracted from the Power Sum NEXT for the pair. The worst case Power Sum ACR is reported for each pair.