D-2Instruction Set Quick Reference

Relay Instructions

Instruction

 

 

 

 

 

Description

 

 

 

 

 

I:012

 

 

 

 

Examine On

Examine data table bit I:012/07, which corresponds to terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XIC

7 of an input module in I/O rack 1, I/O group 2. If this data table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bit is set (1), the instruction is true.

07

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I:012

 

 

 

 

Examine Off

Examine data table bit I:012/07, which corresponds to terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XIO

7 of an input module in I/O rack 1, I/O group 2. If this data table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bit is reset (0), the instruction is true.

07

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O:013

 

 

 

 

Output Energize

If the input conditions preceding this output instruction on the

 

 

 

 

 

(

 

 

)

 

 

 

 

 

OTE

same rung go true, set (1) bit O:013/01, which corresponds to

 

 

 

 

 

 

 

 

 

 

 

 

terminal 1 of an output module in I/O rack 1, I/O group 3.

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O:013

 

 

 

 

Output Latch

If the input conditions preceding this output instruction on the

 

 

 

 

 

( L )

 

 

 

 

 

OTL

same rung go true, set (1) bit O:013/01, which corresponds to

 

 

 

 

 

 

 

 

 

 

 

terminal 1 of an output module in I/O rack 1, I/O group 3. This

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

data table bit remains set even if the rung condition goes false.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O:013

 

 

 

 

Output Unlatch

If the input conditions preceding this output instruction on the

 

 

 

 

 

( U

)

 

 

 

 

 

OTU

same rung go true, reset (0) bit O:013/01, which corresponds to

 

 

 

 

 

 

 

 

 

 

 

terminal 1 of an output module in I/O rack 1, I/O group 3. This is

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

necessary to reset a bit that has been latched on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

 

 

 

 

 

 

 

Immediate Input

This instruction updates a word of input-image bits before the

 

 

 

 

 

( IIN

 

 

)

 

 

 

IIN

next normal input-image update. Address this instruction by

 

 

 

 

 

 

 

 

 

 

 

rack and group (RRG). For a local chassis, program scan is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

interrupted while the inputs of the addressed I/O group are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

scanned; for a remote chassis, program scan is interrupted only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to update the input image with the latest states as found in the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

remote I/O buffer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

 

 

 

 

 

 

 

Immediate Output

This instruction updates a word of output-image bits before the

 

 

 

 

 

( IOT

 

)

IOT

next normal output-image update. Address this instruction by

 

 

 

 

 

 

 

rack and group (RRG). For a local chassis, program scan is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

interrupted while the outputs of the addressed I/O group are updated; for a remote chassis, program scan is interrupted only to update the remote I/O buffer with the latest states as found in the output image.