B-8Processor Status File

This

 

 

Fault

 

 

Code

Indicates this Fault

And the Fault Is

 

 

 

90

Sidecar module extensive memory test failed. Call your Allen-Bradley representative for

Recoverable

 

service

 

 

 

 

91Sidecar module undefined message type

92Sidecar module requesting undefined pool

93Sidecar module illegal maximum pool size

94Sidecar module illegal ASCII message

95Sidecar module reported fault, which may be the result of a bad sidecar program or of a hardware failure

96Sidecar module not physically connected to the PLC-5 controller

97Sidecar module requested a pool size that is too small for PC3 command (occurs at power-up)

98Sidecar module first/last 16 bytes RAM test failed

99Sidecar module-to-controller data transfer faulted

100Controller-to-sidecar module transfer failed

101Sidecar module end of scan transfer failed

102The file number specified for raw data transfer through the sidecar module is an illegal value

103The element number specified for raw data transfer through the sidecar module is an illegal value

104The size of the transfer requested through the sidecar module is an illegal size

105The offset into the raw transfer segment of the sidecar module is an illegal value

106Sidecar module transfer protection violation; for PLC-5/26, -5/46, and -5/86 controllers only

Publication 1785-UM012D-EN-P - July 2005

Page 282
Image 282
Bradley Smoker PLC-5 user manual Recoverable, Service, 8Processor Status File