D-28Instruction Set Quick Reference

Instruction

Description

 

 

AEX

STRING EXTRACT

Source ST38:40

Index42

Number10

DestST52:75

ASCII String Extract

If input conditions are true, the controller extracts 10

AEX

characters starting at the 42nd character of ST38:40 and

 

store the result in ST52:75.

AIC

INTEGER TO STRING CONVERSION

Source

876

Dest

ST38:42

Convert Integer to

If input conditions are true, the controller converts the value

ASCII String

876 to a string and store the result in ST38:42.

AIC

 

AHL

ASCII HANDSHAKE LINE

Channel

0

AND Mask

0001

OR Mask

0003

Control

R6:23

Channel Status

 

ASCII Handshake

Lines

AHL

Status Bits:

EN-Enable

DN-Done Bit

ER-Error Bit

If input conditions go from false-to-true, the controller uses the AND and OR masks to determine whether to set or reset the DTR (bit 0) and RTS (bit 1) lines, or leave them unchanged. Bit 0 and 1 of the AND mask cause the line(s) to reset if 1 and leave the line(s) unchanged if 0. BIt 0 and 1 of the OR mask cause the line(s) to set if 1 and leave the line(s) unchanged if 0.

See page F-8 for a description of prescan operation for this instruction.

ARD

 

 

 

 

ASCII READ

 

Channel

0

Dest

ST52:76

Control

R6:32

String Length

50

Characters Read

ASCII Read

If input conditions go from false-to-true, read 50 characters

ARD

from the buffer and move them to ST52:76. The number of

 

characters read is stored in R6:32.POS and displayed in the

Status Bits

Characters Read Field of the instruction display.

EN - Enable

See page F-8 for a description of prescan operation for this

DN - Done Bit

ER - Error Bit

instruction.

UL - Unload

 

EM - Empty

 

EU - Queue

 

 

ARL

 

 

 

 

 

 

ASCII READ LINE

 

 

Channel

0

 

Dest

ST50:72

 

Control

R6:30

 

String Length

18

 

Characters Read

 

ASCII Read Line

If input conditions go from false-to-true, read 18 characters

ARL

(or until end-of-line) from the buffer and move them to

 

ST50:72. The number of characters read is stored in

Status Bits

R6:30.POS and displayed in the Characters Read Field of the

EN - Enable

instruction display.

DN - Done Bit

 

ER - Error Bit

See page F-8 for a description of prescan operation for this

UL - Unload

instruction.

EM - Empty

 

EU - Queue

 

Publication 1785-UM012D-EN-P - July 2005