Initial Configuration
Table 2-1CDM-570/570L Network Roles and Functions
CDM-570/570L Network Role/Function | Hub | Remote Expansion |
Hub Burst Controller providing STDMA Timing Maps | X | |
Hub Point-to-Point SCPC Modem | X | |
Hub Switched Demodulator | X | X |
Remote STDMA Modem | X | |
Remote Point-to-Point SCPC Modem | X | |
Remote Mesh Demodulator | X | X |
| | |
Setting Vipersat CDM-570/570L Operating
Parameters
The following is an example of using the CLI to bring a Vipersat CDM-570/ 570L with factory default settings to the configuration which allows the Viper- sat functions to be accessible.
When the parameter file (param image) of the CDM-570/570L has either been reset to or still has the factory default configuration, all Vipersat feature and unlock codes in the CDM-570/570L are deleted and all configurations are reset, disabling the Vipersat feature set.
Set the Feature Configuration
The operating parameters that will be configured in the target CDM-570/570L are, in part, determined by the role the CDM-570/570L is to fill in the network, as shown in table 2-1and table 2-2.
Use the following procedure to configure a CDM-570/570L to the network role it is to fill in a Vipersat network.
1.From the Main Menu shown in figure 2-1,select the Administration command by entering A at the command prompt.