Vipersat Configuration
Figure 3-54 Minimum Power Level prompt (CDM-570L)
The value entered sets the minimum power level allowed by all SCPC modula- tors.
Max Step Down Power
The Maximum Step Down Power value sets the largest step reduction in trans- mit power permitted when the DPC is adjusting the power downward to achieve the target set point. The default value for this parameter is 3 dB.
Enter D at the command prompt to display the Max Step Down Power dialog shown in figure
Figure 3-55 Maximum Step Down Power prompt
Max Step Up Power
The Maximum Step Up Power value sets the largest step increase in transmit power permitted when the DPC is adjusting the power upward to achieve the target set point. The default value for this parameter is 3 dB.
Enter U at the command prompt to display the Max Step Up Power dialog shown in figure
Figure 3-56 Maximum Step Up Power prompt
Chapter 3 - Using the Command Line Interface (CLI) |