Vipersat Configuration

Figure 3-41ToS Switching Control screen

ToS Switching Entry

After determining what ToS value to use, either application or router classifier, select a ToS entry from the list for configuration or edit. The screen will prompt for inputs to the list of range-checked values, as shown in the sample dialog in figure 3-42that displays the entries for TOS 03.

Figure 3-42ToS Switching Entry dialog

Enter Name for TOS ID [ ] - At the prompt, enter a user-defined text label for circuit identification.

Enter the TOS ID - Enter an integer value in the range of 1 to 63. Entering a value of 0 will result in no switch.

Enter the Switch Type - Enter an integer value in the range of 64 to 254 at the prompt to inform the VMS what switching policy to use. Entering a value of 0 will result in no switch.

Chapter 3 - Using the Command Line Interface (CLI)

3-33

Page 67
Image 67
Cables to Go CDM-570L manual ToS Switching Entry, 41ToS Switching Control screen