Appendix B:
B.2 FE-100FX
The
15
|
|
| 174240 |
|
| Figure |
|
| Table | ||
|
|
|
|
Cable Type |
| Worst Case Budget | Typical Budget |
|
|
|
|
|
|
|
|
50/125 ∝m fiber |
| 6.0 dB | 9.0 dB |
|
|
|
|
62.5/125 ∝m fiber |
| 9.0 dB | 12.0 dB |
|
|
|
|
100/140 ∝m fiber |
| 15.0 dB | 18.0 dB |
|
|
|
|
The transmitter power levels and receive sensitivity levels listed are peak power levels after optical overshoot. A peak power meter must be used to correctly compare the values given above to those measured on any particular port. If power levels are being measured with an average power meter, add 3 dB to the measurement to compare the measured values to the values listed above.
|