Chapter 3: Installation
3.Verify that a Link exists by checking that the port RX LED is on (flashing green or yellow or on solid green). If the RX LED is off, perform the following steps until it is on:
a.Check that the
b.Verify that the RJ45 connector on the twisted pair segment has the proper pinouts.
c.Check the cable for continuity.
d.Make sure that the twisted pair connection meets dB loss and cable specifications outlined in Section 2.1.2.
e.Confirm that the crossover switch is in the correct position.
If a Link is not established, contact Cabletron Systems Technical Support. Refer to Section 1.7, Getting Help, for details.
3.5.3Connecting a Multimode Segment to the FE-100FX
The
An odd number of crossovers (preferably one) must be
!maintained between devices so that the transmit port of one
CAUTION | device is connected to the receive port of the other device and |
| |
| vice versa. |
| If the fiber optic cable being used has SC style connectors that |
| do not resemble MIC style connectors, or has SC connectors |
| on one end and a different type on the other, such as ST |
| connectors, ensure that the proper crossing over occurs. |
|