Chapter 4: Planning for HSIM-W6 ISDN Configuration

 

 

Table 8 Remote Router: FP3 (Continued)

 

 

 

 

 

 

 

 

 

 

Configuration Section

 

Item

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote Router

 

IPX Address: Network

 

 

 

 

Database

 

 

 

 

 

 

Number, Hop Count and

1001 1 4

 

 

 

 

 

 

 

 

NetWare IPX Routes

 

Ticks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAPs: Server Name,

Serv312_fp 4

1001

 

 

Remote Router

 

Server Type, Network

 

 

 

 

Database

 

Number, Node Number

 

 

 

 

 

 

and Sockets

 

 

 

 

NetWare IPX SAPs

 

 

 

 

 

 

 

 

WAN Network Number

00-00-00-00-00-01

451 789

 

 

 

 

 

 

 

 

a. Used only in PPP numbered mode of addressing b. Used only in PPP numbered mode of addressing

NOTE

Use one chart for each remote router in the remote router database.

Table 9 Remote Router: ISP (Internet Service Provider)

Configuration Section

Item

Setting

 

 

 

 

 

 

Remote Router Database

ISDN Phone #1

5551115

Dial Settings

 

 

 

ISDN Phone #2

5551116

 

Disconnect Timer Value

Default (60 seconds)

 

Maximum Links

Default (1)

 

Minimum Links

Default (0)

 

Threshold

Default (0)

 

Bandwidth Direction

Default (Both)

 

 

 

Remote Router Database

Minimum Authentication

PAP

Dial-In Security

 

 

 

Remote Router’s Password/Secret

ISPpasswd

 

 

 