Pin assignments

The following table lists the signals and input/output status of the pin assignments used for parallel communication. (The names in parentheses show the signals when you use the MultiPASS 1000 as a normal printer.)

No. Signal

I/O

No. Signal

I/O

1

(STROBE)

IN

19

 

STROBE-RET1

 

HOSTCLK

 

 

 

 

 

 

 

 

 

 

 

 

2

(DATA 1)

IN/OUT

20

 

DATA 1-RET

3

(DATA 2)

IN/OUT

21

 

DATA 2-RET

4

(DATA 3)

IN/OUT

22

 

DATA 3-RET

5

(DATA 4)

IN/OUT

23

 

DATA 4-RET

6

(DATA 5)

IN/OUT

24

 

DATA 5-RET

7

(DATA 6)

IN/OUT

25

 

DATA 6-RET

8

(DATA 7)

IN/OUT

26

 

DATA 7-RET

9

(DATA 8)

IN/OUT

27

 

DATA 8-RET

10

 

 

 

 

 

OUT

28

 

 

 

 

 

 

 

-RET

(ACKNLG)

ACKNLG

 

PTRCLK

 

 

 

 

 

 

 

 

 

 

 

 

11

(BUSY) PTRBUSY

OUT

29

 

BUSY-RET

12

(P.E.)

OUT

30

PAPER END-RET

 

ACK DATA REQ

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

XFLAG

OUT

31

 

 

 

 

(SELECT)

(INIT)

14

 

 

2)

 

32

 

 

 

 

 

 

 

 

(AUTO FEED XT

 

(ERROR)

 

HOST BUSY

 

 

 

 

 

 

 

 

 

 

 

 

DATA AVAIL

15

NO CONNECTION

33

 

GND

16

GND

 

34

NO CONNECTION

17

GND

 

35

+5.0V3

18

PERIPHERAL

 

36

 

 

 

 

2)

 

 

(SELECT IN

 

LOGIC HIGH4

 

 

1284 ACTIVE

1All RETs are connected to GND.

2These signals are valid only in Epson LQ printer control mode.

3The level is raised to +5.0V at 3.3k Ω register.

4The level is raised to +5V at 390 Ω register.

IN

OUT

OUT

A-6Specifications