Cisco Systems OL-11497-03 manual Carrying handle Captive screws 2 on each side

Models: OL-11497-03

1 344
Download 344 pages 57.99 Kb
Page 254
Image 254

Chapter 6 Maintaining the Router

Removing and Replacing the Blower Module

Use the following procedure to remove and replace the blower module.

Step 1 Remove the blower module from the chassis (Figure 6-5):

a.Lift the blower module handle to its carrying position.

b.Loosen the four captive screws on the blower module faceplate.

c.Remove the blower module by grasping it on each side and pulling it straight back from the chassis.

Figure 6-5 Removing the Blower Module

1

2

129401

1

Carrying handle

2

Captive screws (2 on each side)

 

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide

6-10

OL-11497-03

Page 254
Image 254
Cisco Systems OL-11497-03 manual Carrying handle Captive screws 2 on each side, Removing the Blower Module