Chapter 5 Field Diagnostics for the Cisco 12000 Series Router

Using the diag Command

Output Examples

The following example shows the output when field diagnostics are performed on the line card in slot 7. After the line card passes all field diagnostic tests, the Cisco IOS software automatically reloads on the card. Before starting the diagnostic tests, you must confirm the request to perform these tests on the line card because all activity on the line card is halted. The total/indiv. timeout set to 2000/600 sec. message indicates that 2000 seconds are allowed to perform all field diagnostics tests, and that no single test should exceed 600 seconds to complete.

Router# diag 7 source tftp

tftp://192.164.5.4/images/c12k-fdiagsbflc-mz.120-25.S

Running DIAG config check

Fabric Download for Field Diags chosen: If timeout occurs, try 'mbus' option.

Running Diags will halt ALL activity on the requested slot. [confirm] award-rp-slot0#

Launching a Field Diagnostic for slot 7

Downloading diagnostic tests to slot 7 via fabric (timeout set to 300 sec.)

5d20h: %GRP-4-RSTSLOT: Resetting the card in the slot: 7,Event:

EV_ADMIN_FDIAG

Loading images/award/c12k-fdiagsbflc-mz from 192.164.1.1 (via

Ethernet0): !!!!!

5d20h: Downloading diags from tftp file tftp://192.164.1.1/images/award/c12k-fdiagsbflc-mz

!!!!![OK - 13976524 bytes]

FD 7> *****************************************************

FD 7> GSR Field Diagnostics V6.05

FD 7> Compiled by award on Tue Jul 30 13:00:41 PDT 2002 FD 7> view: award-conn_isp.FieldDiagRelease

FD 7> *****************************************************

Executing all diagnostic tests in slot 7 (total/indiv. timeout set to 2000/600 sec.)

 

 

FD 7>

BFR_CARD_TYPE_OC12_4P_POS testing...

 

 

FD 7>

Available test types 2

 

 

FD 7>

1

 

 

 

FD 7>

Completed f_diags_board_discovery() (0x1)

 

 

FD 7>

Test list selection received: Test ID 1, Device 0

 

 

FD 7>

running in slot 7 (30 tests from test list ID 1)

 

 

FD 7>

Skipping MBUS_FDIAG command from slot 2

 

 

FD 7>

Just into idle state

 

 

Field

Diagnostic ****PASSED**** for slot 7

 

 

Shutting down diags in slot 7

 

 

Board

will reload

 

 

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide

 

 

5-14

 

 

OL-11497-03

 

 

 

 