Chapter 3 Installing the Router

Power On the Router

Note In a noisy environment, the blowers might be difficult to hear; in that case, place your hand in front of the exhaust vents at the rear of the chassis to verify that the blowers are operating.

Figure 3-21 Alarm Card LEDs On/Off Conditions

MBUS

CSC

 

SFC

 

CRITICALMAJOR

MINOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAIL

 

 

 

 

 

 

 

ENABLED

 

 

 

 

 

66170

0

1

0

1

2

 

 

ALARM

 

 

 

 

1

2

 

3

4

5

6

 

 

1

MBus status LED

4

Critical alarm LED

 

 

 

 

2

CSC status LEDs (two)

5

Major alarm LED

 

 

 

 

3

SFC status LEDs (three)

6

Minor alarm LED

 

 

 

 

Step 5 Visually check the LEDs on the two alarm cards. (See Figure 3-21.) When the system is operating correctly, the following LED conditions should be true.

LEDs that normally should be off:

One MBUS status LED labeled FAIL

Two CSC status LEDs labeled FAIL

Three SFC status LEDs labeled FAIL

Three router alarm LEDs labeled CRITICAL, MAJOR, MINOR LEDs that normally should be on:

One MBUS status LED labeled ENABLED

Two CSC status LEDs labeled ENABLED

Three SFC status LEDs labeled ENABLED

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide