Appendix A Technical Specifications

Specifications

Table A-4

Environmental Specifications

 

 

 

 

Description

 

Value

 

 

 

 

Temperature

 

32° to 104°F (0° to 40°C) operating

 

 

–4° to 149°F (–20° to 65°C) non-operating

 

 

 

Humidity

 

10 to 90% noncondensing operating

 

 

5 to 95% noncondensing non-operating

 

 

 

Altitude

 

0 to 10,000 ft. (0 to 3,000 m) operating

 

 

0 to 15,000 ft. (0 to 4,570m) non-operating

 

 

 

Heat dissipation

5,828

Btu/hr maximum (AC original series)

 

 

8,871

Btu/hr maximum (AC enhanced series)

 

 

5,562

Btu/hr maximum (DC original series)

 

 

8,871

Btu/hr maximum (DC enhanced series)

 

 

 

Cooling

 

Facing the router, right-side-to-back cooling

 

 

 

Shock

 

5 to 500 Hz, 0.5g1 (0.1 oct/min2) operating

 

 

5 to 100 Hz, 1g (0.1 oct/min) non-operating

 

 

100 to 500 Hz, 15g (0.2 oct/min)

 

 

500 to 1,000 Hz, 1.5g (0.2 oct/min)

 

 

 

 

1.g = Gravity

2.oct/min = Octave per minute

Caution Exhaust from other equipment vented directly into the Cisco 12006 and

Cisco 12406 Router air inlet may cause overheating. Install the router so that it is protected from a direct flow of hot air from other equipment.

 

 