Chapter 5 Field Diagnostics for the Cisco 12000 Series Router

Using the diag Command

FD 3> GSR Field Diagnostics V6.01

FD 3> Compiled by award on Tue Apr 9 07:22:53 PDT 2002 FD 3> view: award-conn_isp.f_diag_new

FD 3> *****************************************************

Diagnostics have been downloaded to slot 7 Executing all diagnostic tests in slot 7 (total/indiv. timeout set to 2000/600 sec.)

FD 3> BFRP w/ECC testing...

 

FD 3> Secondary Discovery found ID 2

FD 3> BFR_CARD_TYPE_BFRP_CARD w/ ECC testing...

FD 3> Available test types

2

FD 3>

1

FD 3> Completed f_diags_board_discovery() (0x1)

FD 3> Verbosity now (0x00000011) TESTSDISP FATL

FD 3> Test list selection received: Test ID 1, Device 0

FD 3> running in slot 7 (24 tests from test list ID 1)

FDIAG_STAT_IN_PROGRESS(3): test #1 BFRP Dram Datapins Test

FDIAG_STAT_IN_PROGRESS(3): test #2 Dram Marching Pattern Test

FDIAG_STAT_IN_PROGRESS(3): test #3 DataPins_Sram

FDIAG_STAT_IN_PROGRESS(3): test #4 March_Sram

FDIAG_STAT_IN_PROGRESS(3): test #5 High Memory DRAM Marching Pattern

FDIAG_STAT_IN_PROGRESS(3): test #6 diags_csar_regtest

FDIAG_STAT_IN_PROGRESS(3): test #7 diags_test_p4_csar_int

FDIAG_STAT_IN_PROGRESS(3): test #8 NVRAM Memory Test

FD 3> 32 bit data compare error. Wrote 0xcccccccc, read back

0xcc41cccc at location 0xbe03fff0

FDIAG_STAT_DONE_FAIL(3) test_num 8, error_code 1

COMPLETED Field Diags: pid 128, status 5, test_num 8, error_code 1

Field Diagnostic: ****TEST FAILURE**** slot 7: first test failed: 8, NVRAM Memory Test, error 1

Field Diag results from eeprom before updating slot 7, run# 0x5000042 were 0x0

previous field diag eeprom values: run 66 fail mode 5 (DOWNLOAD FAILURE)

last test failed was 0, error code 0

Field Diag eeprom values: run 67 fail mode 1 (TEST FAILURE) slot 7 last test failed was 8, error code 1

Shutting down diags in slot 7

slot 7 done, will not reload automatically

The following example shows the previous test results of a line card. Diagnostics had been run 64 times on this line card. Because the board PASSED the last field diagnostics session, the fail mode was 0 as was the last test that failed.

Router # diag 7 prev

Field Diag eeprom values: run 64 fail mode 0 (PASS) slot 7 last test failed was 0, error code 0

 

 

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide

 

 

 

 

 

 

OL-11497-03

 

 