Chapter 6 Maintaining the Router

Removing and Replacing a DC PEM

Step 5 Power on the circuit breaker.

Step 6 Set the power switch to the On position.

The AC Input and DC Output power indicators on the front of the power supply should light. If the indicators do not light, or the Miswire indicator is on, see the “Troubleshooting the DC Power Supply Installation” section on page 6-35.

Troubleshooting the DC Power Supply Installation

Use the following procedure to troubleshoot the DC power supply if it is not operating properly after installation.

Step 1 Make sure the power supply is seated properly:

Eject and reseat the power supply.

The captive screw on the ejector lever are tightened securely.

The power switch is set to the On (1) position.

Step 2 Make sure the router is powered on and that all power cables are connected properly:

Power leads are securely connected to the power connector block on the PDU.

Power cables are securely connected at the DC source connection.

The source DC circuit breaker is turned on.

 

 

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide

 

 

 

 

 

 

OL-11497-03

 

 

6-35

 

 

 