Cisco Systems OL-11497-03 manual Removing and Installing a Switch Fabric Card

Models: OL-11497-03

1 344
Download 344 pages 57.99 Kb
Page 305
Image 305

Chapter 6 Maintaining the Router

Removing and Installing a Clock and Scheduler Card, Switch Fabric Card, or Alarm Card

Figure 6-33 Alarm Card LEDs On/Off Conditions

MBUS

CSC

 

SFC

 

CRITICALMAJOR

MINOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAIL

 

 

 

 

 

 

 

ENABLED

 

 

 

 

 

66170

0

1

0

1

2

 

 

ALARM

1

2

 

3

4

5

6

 

 

1

MBus status LED

4

Critical alarm LED

 

 

 

 

2

CSC status LEDs (two)

5

Major alarm LED

 

 

 

 

3

SFC status LEDs (three)

6

Minor alarm LED

 

 

 

 

Removing and Installing a Switch Fabric Card

The three SFCs occupy the three half-width slots on the lower right side of the chassis. (See Figure 6-31.) Figure 6-34shows a partially-ejected SFC.

Note Two CSCs (redundant configuration) are required to support CSC online insertion and removal (OIR). This allows you to remove and replace a CSC or an SFC while the system remains powered on. If only one CSC is present, do not remove any cards while the system is powered on.

Caution When removing an SFC, remove the card entirely from the chassis and place it in an ESD-safe environment. Do not allow the card to rest partially inserted into the slot, as this damages the EMI shielding on the card in the slot directly below.

Procedures for removing and installing an SFC are described in these sections:

Removing a Switch Fabric Card, page 6-62

Installing a Switch Fabric Card, page 6-63

Verifying the Installation of the Switch Fabric Card, page 6-64

Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide

 

OL-11497-03

6-61

 

Page 305
Image 305
Cisco Systems OL-11497-03 manual Removing and Installing a Switch Fabric Card, Alarm Card LEDs On/Off Conditions