Mirror drives contain copy of data

CXO5511A

Figure 3–5. Mirrorsets Maintain Two Copies of the Same Data

Considerations for Planning a Mirrorset

Keep these points in mind as you plan your mirrorsets:

A controller can support up to 30 storagesets, consisting of mirrorsets and RAIDsets. Mirrorsets that are members of a stripeset count against this limitation (see Table 3–1).

Data availability with a mirrorset is excellent but costly—you need twice as many disk drives to satisfy a given capacity requirement. If availability is your top priority, consider using redundant power supplies and dual-redundant controllers.

You can configure up to 30 mirrorsets per controller or pair of dual-redundant controllers. Each mirrorset contains a minimum of one member and a maximum of six members.

A write-back cache module is required for mirrorsets, but write-back cache need not be enabled for the mirrorset to function properly.

Both write-back cache modules must be the same size.

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide