Connecting in Multiple-Bus Failover Mode to the Host

Use the following steps and Figure 2–3to connect a pair of multiple-bus failover, dual-redundant controllers to the host:

1.Configure both controllers. See “Configuring Dual-Redundant Controllers in Multiple-Bus Failover Mode,” page 2–16.

2.Ensure the host and adapter are also configured. See the host user’s guide for details.

3.Connect a trilink connector on host Port 1 or host Port 2 for one controller:

a.Connect the host bus cable onto one end of each trilink connector.

b.For a BA370 enclosure residing in an SW600 cabinet, snap the ferrite bead on the bus cable within one inch of the controller.

4.Connect another trilink connector on host Port 1 or host Port 2 for a second controller:

a.Connect the host bus cable onto one end of each trilink connector.

b.For a BA370 enclosure residing in an SW600 cabinet, snap the ferrite bead on the bus cable within one inch of the controller.

5.Connect a terminator on the end of each trilink connector:

a.If the controller is at the end of the host bus, connect a terminator to the other connector on the front of the trilink connector.

b.Otherwise, connect another host bus cable that continues to the next device on the bus. Be sure to install a terminator at the end of the bus.