4–7

4.Verify the RAIDset configuration and switches. Use the following syntax:

SHOW RAIDset-name

5.Verify the unit configuration and switches. Use the following syntax:

SHOW unit-number

Example

The following example shows the commands you would use to create RAID1, a three- member RAIDset:

ADD RAIDSET RAID1 DISK10000 DISK20000 DISK30000

INITIALIZE RAID1

ADD UNIT D300 RAID1

SHOW RAID1

SHOW D300

Configuring a Striped Mirrorset

See “Creating a Storageset and Device Profile,” page 3–5for information about creating a profile and understanding the switches you can set for this kind of storage unit.

NOTE: A striped mirrorset cannot be created if the mirrorsets are enabled for

DT_SUPPORT.

To configure a striped mirrorset:

1.Create—but do not initialize—at least two mirrorsets.

2.Create a stripeset and specify the mirrorsets it contains. Use the following syntax:

ADD STRIPESET stripeset-name mirrorset_1 mirrorset_2

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide

Page 155
Image 155
Compaq HSZ80 manual Configuring a Striped Mirrorset, Show RAIDset-name, ADD Stripeset stripeset-name mirrorset1 mirrorset2