5–21

Specify NORMAL to balance other controller operations with the reconstruct operation. The controller uses relatively few resources to perform the reconstruct process: there is little impact on performance.

REDUCED

NOREDUCED (Default)

Permits the addition of a RAIDset missing a member. Specify the REDUCED switch when you add a reduced RAIDset (a RAIDset that is missing a member).

Specify the NOREDUCED switch when all the disks making up the RAIDset are present—for instance, when creating a new RAIDset.

Verify the RAIDset contains all but one of its disks before specifying the REDUCED switch.

Examples

This example shows how to create a RAIDset named RAID9 that contains disks DISK10000, DISK20100, and DISK30200.

ADD DISK DISK10000 1 0 0

ADD DISK DISK20100 2 1 0

ADD DISK DISK30200 3 2 0

ADD RAIDSET RAID9 DISK10000 DISK20100 DISK30200

This example shows how to create a RAIDset named RAID8 that contains disks DISK10000, DISK20100, and DISK30200, and uses the BEST_FIT switch to indicate the replacement policy. Enter the ADD RAIDSET command on one line.

ADD DISK DISK10000 1 0 0

ADD DISK DISK20100 2 1 0

ADD DISK DISK30200 3 2 0

ADD RAIDSET RAID8 DISK10000 DISK20100 DISK30200 POLICY=BEST_FIT

This example creates RAIDset RAID8, and then creates a host-addressable unit.

INITIALIZE RAID8

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide

Page 207
Image 207