5–25

Examples

This example shows how to create a stripeset named STRIPE1 with three disks: DISK10000, DISK20100, and DISK30200:

ADD DISK DISK10000 1 0 0

ADD DISK DISK20100 2 1 0

ADD DISK DISK30200 3 2 0

ADD STRIPESET STRIPE1 DISK10000 DISK20100 DISK30200

This example show how to create a stripeset named STRIPE1 and then create a logical unit from it:

INITIALIZE STRIPE1

ADD UNIT D103 STRIPE1

This example shows how to create a two-member striped mirrorset (a stripeset whose members are mirrorsets), and how to create a logical unit from it. Because you can initialize the stripeset, you do not need to individually initialize the mirrorsets.

ADD DISK DISK10000 1 0 0

ADD DISK DISK20100 2 1 0

ADD DISK DISK30200 3 2 0

ADD DISK DISK40300 4 3 0

ADD MIRRORSET MR1 DISK10000 DISK20100

ADD MIRRORSET MR2 DISK30200 DISK40300

ADD STRIPESET STRIPE1 MR1 MR2

INITIALIZE STRIPE1

ADD UNIT D104 STRIPE1

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide

Page 211
Image 211
Compaq HSZ80 manual ADD Stripeset STRIPE1 DISK10000 DISK20100 DISK30200, Initialize STRIPE1 ADD Unit D103 STRIPE1