2–22Configuring an HSZ80 Array Controller

6.Repeat steps 3, 4, and 5 for connecting a third and a fourth host bus.

IMPORTANT: The HSZ80 Array Controller has dual-host ports, Port 1 and Port 2, which may be configured at the same time. The configuration in Figure 2–3shows a two-bus connection going into host Port 1. However, you may also con- figure host Port 2 the same way, depending on your system requirements. For a two-bus connection, the bus connections can occur on either host port on two controllers. A third and fourth bus connection can also be made if three or four buses are desired.

Optional Steps

You can perform these steps at any time during configuring.

Change the CLI prompt

Enter a 1- to 16-character string as the new prompt. For example, you could use the prompt to indicate the controller’s name, such as “HSZ>.”

Type the following command:

SET THIS_CONTROLLER PROMPT = “new prompt”

If you are configuring dual-redundant controllers, also change the CLI prompt on the other controller. Use the following command:

SET OTHER_CONTROLLER PROMPT = “new prompt”

See “SET controller” in Chapter 5, “CLI Commands.”

Page 76
Image 76
Compaq manual Optional Steps, Change the CLI prompt, 22Configuring an HSZ80 Array Controller