5–121

Specify NODESTROY_UNFLUSHABLE_DATA to leave the unwritten data intact in the failed controller’s write-back cache. When the failed controller is replaced and placed into service, the write-back cache data is flushed to the appropriate devices.

Specify DESTROY_UNFLUSHABLE_DATA to reconfigure the operational controller before replacing the failed controller. The unwritten data of the failed controller may reference devices not present in the new configuration. If you do not destroy the old configuration data, it may conflict with the new configuration and cause the subsystem to behave unpredictably.

CAUTION: Unflushed data cannot be recovered after it is destroyed.

Example

This example shows how to terminate failover mode between two controllers in a dual-redundant configuration:

SET NOFAILOVER

See also

SET FAILOVER

SET MULTIBUS_FAILOVER

SET NOMULTIBUS_FAILOVER

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide