5–119

Due to the amount of information being passed from one controller to the other, this command may take up to one minute to complete.

Example

This example shows how to configure two controllers to operate in dual-redundant mode within a multiple bus environment:

SET THIS_CONTROLLER PORT_1_ID=(0,1,2,3)

RESTART THIS_CONTROLLER

SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER

The configuration on “this controller” is automatically copied to the “other controller” when you issue the SET MULTIBUS_FAILOVER COPY command. If you want to prefer specific units to specific controllers, use the following command after setting multiple bus failover:

SET D100 PREFERRED_PATH=THIS_CONTROLLER

SET D101 PREFERRED_PATH=OTHER_CONTROLLER

See also

SET FAILOVER

SET NOFAILOVER

SET NOMULTIBUS_FAILOVER

Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide

Page 305
Image 305
Compaq HSZ80 manual 119, SET Failover SET Nofailover SET Nomultibusfailover