1–24General Description

Table 1–8 Cache Policies and Cache Module Status (Continued)

Cache Module Status

Cache Policy

 

 

 

 

Cache A

Cache B

Unmirrored Cache

Mirrored Cache

 

 

 

 

DIMM or

Good

Data integrity: Write-back data that

Data integrity: Controller A recovers all

cache

 

was not written to media when

of its write-back data from the

memory

 

failure occurred was not recovered.

mirrored copy on cache B.

controller

 

Cache policy: Controller A supports

Cache policy: Controller A supports

chip

 

 

write-through caching only;

write-through caching only; controller

failure

 

 

controller B supports write-back

B supports write-back caching.

 

 

 

 

caching.

Failover: In transparent failover, all

 

 

 

 

 

Failover: In transparent failover, all

units failover to controller B and

 

 

units failover to controller B. In

operate normally. In multiple-bus

 

 

multiple-bus failover with host-

failover with host-assist, only those

 

 

assist, only those units that use

units that use write-back caching,

 

 

write-back caching, such as

such as RAIDsets and mirrorsets,

 

 

RAIDsets and mirrorsets, failover to

failover to controller B.

 

 

controller B. All units with lost data

 

 

 

become inoperative until you clear

 

 

 

them with the CLEAR LOST_DATA

 

 

 

command. Units that didn’t lose data

 

 

 

operate normally on controller B.

 

 

 

In single controller configurations,

 

 

 

RAIDsets, mirrorsets, and all units

 

 

 

with lost data become inoperative.

 

 

 

Although you can clear the lost data

 

 

 

errors on some units, RAIDsets and

 

 

 

mirrorsets remain inoperative until

 

 

 

you repair or replace the nonvolatile

 

 

 

memory on cache A.

 

 

 

 

 

 

 

 

 