4–10Configuring Storagesets

See “ADD UNIT,” page 5–27,for valid switches and values.

NOTE: If you make a disk transportable, you cannot specify WRITEBACK_CACHE for that disk.

4.Verify the configuration using the following command:

SHOW DEVICES

Example

The following example shows the commands you would use to configure DISK10000 as a single-disk unit.

ADD DISK DISK10000 1 0 0

ADD UNIT D101 DISK10000

SHOW DEVICES

Partitioning a Storageset or Disk Drive

See “Planning Partitions,” page 3–40,for details about partitioning a storage unit. Partitioning cannot be used in multiple bus failover mode.

To partition a storageset or disk drive:

1.Add the storageset or disk drive to the controller’s list of storagesets and specify the disk drives it contains. Use the following syntax:

ADD storageset-name DISKnnnn DISKnnnn

or

ADD DISK DISKnnnn ptl-location

Do not split partitioned units across ports. They must be on a single port.

Page 158
Image 158
Compaq HSZ80 manual Partitioning a Storageset or Disk Drive, 10Configuring Storagesets