Compaq HSZ80 manual SCSIVERSION=SCSI-2 Default, SCSIVERSION=SCSI-3, TIME=dd- mmm- yyyyhhmmss

Models: HSZ80

1 386
Download 386 pages 41 Kb
Page 285
Image 285

5–99

SCSI_VERSION=SCSI-2 (Default)

SCSI_VERSION=SCSI-3

Specifies the host protocol to use; requires operating system support. SCSI-3 is limited SCSI-3. It also specifies how the command console LUN is handled. The command console LUN (CCL) presents to the GUI a virtual LUN through which it communicates with the controller.

SCSI-2 specifies that the CCL is not fixed at a particular location, but floats depending on the configuration.

SCSI-3 specifies that the LLC is fixed at LUN 0. The SCSI device-type returned to the host is array controller.

Changes to this switch take place at the next controller restart.

TERMINAL_PARITY=ODD

TERMINAL_PARITY=EVEN

NOTERMINAL_PARITY (Default)

Specifies the parity with which data is transmitted and received. When changed, the new setting for this switch takes effect immediately.

TERMINAL_SPEED=baud_rate

TERMINAL_SPEED=9600 (Default)

Sets the terminal transmission and reception speed (baud rate) to 4800, 9600 (default), or 19200 baud. When changed, the new value entered for this switch takes effect immediately.

TIME=ddmmmyyyy:hh:mm:ss

Sets the date and time using a 24-hour clock. The time is set on both controllers in a dual-redundant configuration.When changed, the new value entered for this switch takes effect immediately.