5–74CLI Commands

POWEROFF

Powers off all disk units in a cabinet and turns off the cabinet power in all cabinets associated with the controller.

Syntax

POWEROFF

Switches

BATTERY _ON

BATTERY_OFF (Default)

Instructs the external cache battery (ECB) charger to turn off or remain on.

Specify BATTERY_ON to keep the ECB powering the cache module after the cabinet is powered off.

Specify BATTERY_OFF to disable the cache batteries after the cabinet is powered off.

NOTE: The ECB LEDs will continue to flash in both cases, but the cache module

LEDs cease flashing when BATTERY_OFF is chosen.

OVERRIDE_BAD_FLUSH

NO_OVERRIDE_BAD_FLUSH (Default)

Instructs the controller to either poweroff the cabinet or remain on depending on the cache flush results.

Specify OVERRIDE_BAD_FLUSH to override a failed cache flush and poweroff the cabinet.

Specify NO_OVERRIDE_BAD_FLUSH to prevent a poweroff when the cache flush fails.

Page 260
Image 260
Compaq HSZ80 manual Poweroff, 74CLI Commands, Battery on, Overridebadflush